Low voltage earthing equipments

Mod. ECBT-MPUE Mod. ECBT-MPUBTH
Low voltage electric panels Low voltage electric panels
ECBT-MPUE_300X300 ECBT-MPUBTH_300X300
Earthing and short-circuit equipment for low voltage electric panels. The main aim for its installation is operator’s protection against an accidental commissioning or possible voltage return during repair operations. The MPUE clamps can be fixed on bare cylindrical conductors, flat bars, bending bus-bars or fixing points. Each one has its own fixed handle.

  • Composed of:
  • 4 MPUE aluminium alloy clamps with screw tighten and insulated grip for cylindrical conductors with diameter between 4 and 30mm, flat bars max. 45mm, bending bus-bars max. 45mm and fixing points between Ø 20 and 25mm.
  • 3 copper cables with PVC insulation of 35mm2 section and 0,6m long.
  • 1 copper cable with PVC insulation of 25mm2 section and 2m long.
  • 1 TT-38A milling earthing lathe.
  • 1 plastic case to store and transport the equipment.
Earthing and short-circuit equipment for low voltage electric panels. The main aim for its installation is operator’s protection against an accidental commissioning or possible voltage return during repair operations. The MPUBTH clamps for low voltage are perfect to be fixed on flat bars.

  • Composed of:
  • 4 MPUBTH aluminium alloy clamps with screw tighten.
  • 1 insulated grip with polivalent head.
  • 3 copper cables with PVC insulation of 35mm2 section and 0,6m long.
  • 1 copper cable with PVC insulation of 25mm2 section and 2m long.
  • 1 TT-38A milling earthing lathe.
  • 1 plastic case to store and transport the equipment.
PDF PDF
Mod. ELBT-CC Mod. ELBT-PAT/CC
Low voltage overhead lines Low voltage overhead lines
ELBT-CC_300X300 ELBT-PAT-CC_300X300
Short-circuit equipment for low voltage overhead lines. The main aim for its installation is operator’s protection against an accidental commissioning or possible voltage return during repair operations. The ELBT clamp is installed on the bare conductor by leaning it on this one and pressing downwards. The clamp mechanism guarantees a permanent and steady contact.

  • Composed of:
  • 4 ELBT spring clamps with 70cm poles for cylindrical conductors with diameter between 3 and 18mm.
  • 3 copper cables with PVC insulation of 16mm2 section and 0,6m long.
  • 1 nylon bag to store and transport the equipment.
Earthing and short-circuit equipment for low voltage overhead lines. The main aim for its installation is operator’s protection against an accidental commissioning or possible voltage return during repair operations. The ELBT clamp is installed on the bare conductor by leaning it on this one and pressing downwards. The clamp mechanism guarantees a permanent and steady contact.

  • Composed of:
  • 4 ELBT spring clamps with 70cm poles for cylindrical conductors with diameter between 3 and 18mm.
  • 3 copper cables with PVC insulation of 16mm2 section and 0,6m long.
  • 1 copper cable with PVC insulation of 16mm2 section and 15m long.
  • 1 TT-38A milling earthing lathe.
  • 1 earthing rod.
  • 2 nylon bags to store and transport the equipment.
PDF PDF
Mod. ECBT-NH Mod. ECBT-PTA3
Low voltage electric panels Low voltage electric panels
ECBT-NH_300X300
Earthing and short-circuit kit for low-voltage distribution boards. The main reason for their installation is to protect the worker from accidental power-on or return of voltage during repair work.With insulated pole for extracting blades using M-10 screw. According to IEC 61230 standard.

  • Composed of:
  • 3 disconnecting and earthing NH1-3 blades.
  • 3 copper PVC-insulated cables 25 mm² section and 0.2 – 0.4 – 0.6 m for short circuit of phases.
  • 1 copper PVC-insulated cables 25 mm² section and 0.5 long for earthing.
  • 1 insulated pole for placing blades.
  • 1 TT-38A earthing lathe.
  • 1 metal case for storage and transport.
Earthing and short-circuit kit for low-voltage distribution boards. The main reason for their installation is to protect the worker from accidental power-on or return of voltage during repair work.With insulated pole for extracting blades using M-10 screw. According to IEC 61230 standard.

  • Composed of:
  • 3 insulated PTA earth clamps.
  • 3 copper PVC-insulated cables 25 mm² section and 0.4 m long for short circuit of phases.
  • 1 copper PVC-insulated cables 25 mm² section and 1 m long for earthing.
  • 1 branch-joint connector (4 cables).
  • 1 TT-38A earthing lathe.
  • 1 metal case for storage and transport.
PDF PDF
Mod. ECBT-PTA4 Mod. ECBT-ID
Low voltage electric panels Low voltage electric panels
Earthing and short-circuit kit for low-voltage distribution boards.The main reason for their installation is to protect the worker from accidental power-on or return of voltage during repair work. According to IEC 61230 standard.

  • Composed of:
  • 4 insulated PTA earth clamps and the neutral.3 copper PVC-insulated cables 25 mm² section and 1,2 m long for short circuit of phases.
  • 1 copper cables 25 mm² section and 1,5 m long for the neutral’s earthing.
  • 1 PVC-insulated cable 25 mm² section and 2 m long for earthing.
  • 1 branch-joint connector (5 cables).
  • 1 TT-38A earthing lathe.
  • 1 metal case for storage and transport.
Earthing and short-circuit kit for low-voltage distribution boards.The main reason for their installation is to protect the worker from accidental power-on or return of voltage during repair work.With insulated pole for extracting blades using M-10 screw. According to IEC 61230 standard.

  • Composed of:
  • 3 disconnecting and earthing NH00 blades.
  • 3 disconnecting and earthing NH1-3 blades.
  • 3 copper PVC-insulated cables 25 mm² section for short circuit of phases (0.45 – 0.60 – 0.85 m), connected to a branch-joint connector (2/3) from which runs a 1 m copper PVC-insulated cables 25 mm² section for earthing and 0,75 m copper PVC-insulated cables 25 mm² section for neutral.
  • 1 insulated PTA neutral clamp.
  • 1 MPUCN neutral clamp.
  • 1 insulated pole for placing blades.
  • 1 TT-38A earthing lathe.
  • 1 metal case for storage and transport.
PDF PDF
Mod. ECBT-GNF INSULATED COPPER CABLES
Low voltage electric panels Accessories for low voltage electric panels
ECBT-GNF_300X300 accessories_300X300
Earthing and short-circuit kit for low-voltage distribution boards. The main reason for their installation is to protect the worker from accidental power-on or return of voltage during repair work. With insulated pole for extracting blades using M-10 screw. According to IEC 61230 standard.

  • Composed of:
  • 3 disconnecting and earthing NH1-3 blades.
  • 4 disconnecting and earthing MPUCF clamp.
  • 3 copper PVC-insulated cables 35/50 mm² section and 0.45 – 0.60 – 0.85 m long for short circuit of phases.
  • 1 copper PVC-insulated cables 35/50 mm² section and 0.75 m long for neutral.
  • 1 copper PVC-insulated cables 35/50 mm² section and 1 m long for earthing.
  • 1 branch-joint connector (5 cables).
  • 1 insulated pole for placing blades.
  • 1 MPUC neutral clamp.
  • 1 TT-38A earthing lathe.
  • 1 nylon bag for storage and transport.
Copper PVC-insulated cables from 25 to 50 mm² section for short circuit of phases, connected to a trifurcating joint from which runs a copper PVC-insulated cable from 25 to 50 mm² section for earthing and a copper PVC-insulated cable from 25 to 50 mm² section for neutral.
PDF PDF
BLADES CLAMPS
Accessories – Disconnecting and earthing blades Accessories – Earth clamps
Blades_300X300
PDF PDF
Mod. PC Mod. Metal Case
Accessories – Insulated pole for placing blades Accessories – Metal carry case
PC_300X300 Case_300X300
PDF PDF