| Mod. ECBT-MPUE | Mod. ECBT-MPUBTH | |
|
|
||
| Low voltage electric panels | Low voltage electric panels | |
|
|
![]() |
|
| Phase earthing and short-circuit equipment for low voltage electric panels.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The MPU clamps can be fixed on bare cylindrical conductors, fixed points or flat bars. Each one has its own fixed handle. |
Phase earthing and short-circuit equipment for low voltage electric panels.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The MPUBT clamp for low voltage is perfect to be fixed on flat bars. |
|
| Mod. ECBT-PAT/CC | Mod. PATF-MPU | |
|
|
||
| Low voltage electric panels | Unipolar earthing equipment | |
|
|
![]() |
|
| Phase earthing and short-circuit equipment for low voltage electric panels.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. It has an insulated lever suitable for extraction of blade fuses with M-10 connection. |
Earthing equipment for electrical traction lines (catenaries). It has a MPU/B or MPU/H
clamp which allows the earthing connection of the lines for repair operations. |
|
| Mod. ELBT-CC | Mod. ELBT-PAT/CC | |
|
|
||
| Low voltage overhead lines | Low voltage overhead lines | |
|
|
![]() |
|
| Phase earthing and short-circuit equipment for low voltage overhead lines.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The ELBT clamp is placed by pressing a bare conductor by spring. The clamp mechanism grants a permanent and persistent contact. |
Phase earthing and short-circuit equipment for low voltage overhead lines.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The ELBT clamp is placed by pressing a bare conductor by spring. The clamps mechanism grants a permanent and persistent contact. |
|
| Mod. PATL-MPUB | Mod. PATL-MC | |
|
|
||
| Medium voltage overhead lines – Screw clamps | Medium voltage overhead lines – Automatic clamps | |
|
|
![]() |
|
| Phase earthing and short-circuit equipment for medium voltage overhead lines.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The MPU clamp is fixed on bare conductors by screw-tightening. This equipment has got a MPUP clamp (carrier) which facilitates to put up the three clamps at the same time, reducing installation time considerably. In accordance with IEC 61230 standard. |
Phase earthing and short-circuit equipment for medium voltage overhead lines.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The MC clamp is fixed on bare conductors by pressure and removed by an operating hook. The three clamps can be put up at the same time thanks to the dispenser head, facilitating operator’s work. In accordance with IEC 61230 standard. |
|
| Mod. PATC-5014H | Mod. PATC-MPUB | |
|
|
||
| Medium voltage substations – Driver clamps | Medium voltage substations – Screw clamps | |
![]() |
|
![]() |
| Phase earthing and short-circuit equipment for medium voltage substations.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. The 5014 clamp is perfect for difficult access areas. The clamp can be adjusted depending on the inclination required thanks to its multi-directional head system. In accordance with IEC 61230 standard. |
Phase earthing and short-circuit equipment for medium voltage substations. The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations.
The MPU clamp is fixed on bare cylindrical conductors, fixed points or flat bars by screw tightening. In accordance with IEC 61230 standard. |
|
| Mod. PATL-TML | Mod. PATC–TMC | |
|
|
||
| High voltage overhead lines | High voltage substations | |
|
|
![]() |
|
| Phase earthing and short-circuit equipment for high voltage overhead lines.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. In accordance with IEC 61230 standard. |
Phase earthing and short-circuit equipment for high voltage substations.
The main aim for its installation is the operator’s protection against an accidental commissioning or possible return voltage during repair operations. In accordance with IEC 61230 standard. |
|